Método para a determinação de hexazinone e tebutiuron em água.
No hay miniatura disponible
Fecha
Título de la revista
ISSN de la revista
Título del volumen
Editor
Resumen
Descripción
This work presents an alternative method for determination of the herbicides tebuthiuron and hexazinone in ground water. The extraction was made with dichloromethane and the analyses by high performance liquid chromatography (HPLC), using reversed-phase column, C-18, mobile phase methanol/water 50:50, v/v, detection and quantification at 247 nm. The following validation parameters were obtained: limit of detection of method 0.02 and 0.03 ug L-1, limit of quantification of method 0.07 and 0.09 ?g L-1; linear range limit of quantification of instrument - 300 ug L-1 (r2 ? 0.998); recoveries from 90.3 to 108.2% and 90.3 to 101.6%; intermediary precision (%RSD) < 8 and < 6%, for hexazinone and tebuthiuron, respectively. The method showed to be efficient and reliable for determination of the herbicides in ground water.
Palabras clave
Aqüífero Guarani, Monitoramento, Metodologia, Validação, Agrotóxico, Resíduo, Cana de açúcar, Qualidade da água, Poluição da água, Análise química, Método, Monocultura, Lixiviação, Efeito Residual