Capacitive probe calibration in eutroferric red nitosol cultivated with irrigated forages.

dc.contributorArthur Carniato Sanches, ESALQ/USP; Débora Pantojo de Souza, ESALQ/USP; Fernanda Lamede Ferreira de Jesus, ESALQ/USP; Rodolfo Guertas Maffei, ESALQ/USP; Fernando Campos Mendonça, ESALQ/USP; JOSE RICARDO MACEDO PEZZOPANE, CPPSE.
dc.creatorSANCHES, A. C.
dc.creatorSOUZA, D. P. de
dc.creatorJESUS, F. L. F. de
dc.creatorMAFFEI, R. G.
dc.creatorMENDONÇA, F. C.
dc.creatorPEZZOPANE, J. R. M.
dc.date2017-10-27T09:25:52Z
dc.date2017-10-27T09:25:52Z
dc.date2017-10-26
dc.date2017
dc.date2018-08-22T11:11:11Z
dc.date.accessioned2026-07-07T05:26:29Z
dc.descriptionKnowledge of soil water content is important for proper irrigation management because it allows estimating the required amount of water to be applied at the correct time. Capacitance sensors are an alternative of quantification of soil water content (?, cm3 cm-3 ), providing depth readings in a practical and fast way. A capacitive probe (Diviner 2000®) was calibrated in a eutroferric red nitosol cultivated with irrigated forages at the experimental area of ESALQ/USP in the city of Piracicaba - SP, Brazil. Four access tubes were installed and every 2 weeks samples were collected with 3 replicates for each depth level, by the end of 8 weeks starting from ?saturated. Readings were taken with the equipment for every 0.1 m of soil up to 0.7 m of depth, together with the collection of soil samples for the determination of ? in the laboratory. A power equation was developed for each depth studied as well as for the whole soil profile. The proposed general calibration curve (SF = 0,256*?current 0.3422), adjusted by regression analysis, was significantly related to the measurements of the equipment, with high correlation (r 2 = 0.87), and standard error of 0.022 cm3 cm-3 . The calibration for each depth has shown higher coefficients of correlation at the lower depths, minimizing the error of the estimates. On-site calibration allowed better accuracy of soil water monitoring and, thus, provide better irrigation management.
dc.formatp. 1-10.
dc.identifierIn: INOVAGRI INTERNATIONAL MEETING, 4.; CONGRESSO NACIONAL DE IRRIGAÇÃO E DRENAGEM, 26.; SIMPÓSIO BRASILEIRO DE SALINIDADE, 3., 2017, Fortaleza. Anais... Fortaleza: INOVAGRI: ABID; UFC, 2017.
dc.identifierhttp://www.alice.cnptia.embrapa.br/alice/handle/doc/1078230
dc.identifierhttp://dx.doi.org/10.7127/iv-inovagri-meeting-2017-res1900232
dc.identifier.urihttp://hdl.handle.net/123456789/491295
dc.languageeng
dc.rightsopenAccess
dc.subjectSensor
dc.subjectFrequency domain reflectometry
dc.subjectirrigation management
dc.titleCapacitive probe calibration in eutroferric red nitosol cultivated with irrigated forages.